HV Cable Distribution Boxes

DFW8-12 HV Cable Distribution Box

European-style 12 kV cable branching box with double-side doors and butt-sleeve busbars — compact, neat cable layout, DIN 47636 joints, 630 A bolted connectors.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Ambient −30 °C … +40 °C; wind ≈ 34 m/s (≤ 700 Pa)
  • Daily / monthly average RH ≤ 95 %
  • Seismic: horizontal ≤ 0.4 m/s², vertical ≤ 0.15 m/s²; site tilt ≤ 3°
  • Air free of corrosive or flammable gas and heavy vapour; no severe vibration
At a glance

Built to perform, year after year

12 kV / 630 A
Rated voltage / current
50 kA / 0.3 s
Dynamic withstand current
20 kA / 3 s
Thermal withstand current
42 kV / 52 kV
1 min PF withstand / 15 min DC withstand
A closer look

Engineered around safety, efficiency and uptime

Overview

The European-style cable distribution box is widely used in cable engineering of distribution networks. With double-side door opening and butt-joint sleeves as connecting busbars, it offers small overall length, tidy cable arrangement, and three-core cables need no large-span crossing. Cable joints comply with DIN 47636; 630 A bolted fixed-type joints are standard.

Flexible branching

Where site space rules out a cabinet, cable joints can be combined directly into multi-circuit branches without busbars and laid in trenches — e.g. four circuits per phase from two front joints, two rear joints and one butt sleeve, with insulator and semi-conductive end caps sealing the rear ends. Branches can be expanded or reduced at will, housed in an enclosure or directly buried.

Service conditions

Ambient −30 °C … +40 °C; wind ≈ 34 m/s (≤ 700 Pa)
Daily / monthly average RH ≤ 95 %
Seismic: horizontal ≤ 0.4 m/s², vertical ≤ 0.15 m/s²; site tilt ≤ 3°
Air free of corrosive or flammable gas and heavy vapour; no severe vibration

Technical specifications

Full specifications

Technical parameters
Rated voltage / current
12 kV / 630 A
Dynamic withstand current
50 kA / 0.3 s
Thermal withstand current
20 kA / 3 s
1 min PF withstand / 15 min DC withstand
42 kV / 52 kV
Lightning impulse withstand
105 kV
Enclosure protection class
IP33
Models & dimensions (mm)
DFW12-2 / 12-3
640×600×1000
DFW12-4
740×600×1000
DFW12-5
940×600×1000
DFW12-6
1040×600×1000
DFW12-7 / 12-8 / 12-9
1140×600×1000

Specifications are representative and may vary by configuration and region. Final figures are confirmed on the project datasheet.