Vacuum Circuit Breakers

VS1-12 Indoor Vacuum Circuit Breaker

Fixed indoor 12 kV breaker with mechanism-body integration and solid-sealed poles — up to 4000 A / 40 kA, 20,000 mechanical operations and 50 full-fault interruptions; mates with XGN fixed switchgear.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Ambient −15 °C … +40 °C (storage/transport to −30 °C); altitude ≤ 1000 m (insulation uprated for higher sites)
  • Daily RH ≤ 95 %, vapour pressure ≤ 1.8×10⁻³ MPa; seismic ≤ 8
  • No fire, explosion, heavy pollution, chemical corrosion or severe vibration
At a glance

Built to perform, year after year

12kV
Rated / max voltage
630 – 4000 A
Rated current
20·25 / 31.5 / 40 kA
Short-circuit breaking current
50·63 / 80 / 100kA
Making & peak withstand (peak)
A closer look

Engineered around safety, efficiency and uptime

Overview

The VS1-12 indoor fixed HV vacuum breaker (three-phase 50 Hz, 12 kV) controls and protects electrical facilities in industry, power plants and substations, and suits frequent-operation duty. The operating mechanism is integrated with the breaker body as a fixed unit; the main circuit can adopt integral solid-sealed poles for miniaturisation, high reliability and maintenance-free service, mating with XGN-series fixed switchgear.

Service conditions

Ambient −15 °C … +40 °C (storage/transport to −30 °C); altitude ≤ 1000 m (insulation uprated for higher sites)
Daily RH ≤ 95 %, vapour pressure ≤ 1.8×10⁻³ MPa; seismic ≤ 8
No fire, explosion, heavy pollution, chemical corrosion or severe vibration

Technical specifications

Full specifications

Ratings
Rated / max voltage
12 kV
Rated current
630 – 4000 A
Short-circuit breaking current
20·25 / 31.5 / 40 kA
Making & peak withstand (peak)
50·63 / 80 / 100 kA
4 s withstand current
20·25 / 31.5 / 40 kA
PF / impulse withstand (earth · break)
42·48 kV / 75·85 kV
Operating sequence
分-0.3s-合分-180s-合分
Mechanism & life
Mechanical life / fault interruptions
20000 / 50 次
Closing & opening voltage
AC·DC 110 / 220 V
Contact gap / over-travel
11±1 mm / 3.5±0.5 mm
Bounce time
≤ 2 ms
Average opening / closing speed
0.9–1.2 / 0.5–0.8 m/s
Opening time (max voltage)
≤ 0.05 s

Specifications are representative and may vary by configuration and region. Final figures are confirmed on the project datasheet.