Distribution & Metering Boxes

JP Outdoor Integrated Distribution Box

Pole-mounted all-in-one box for 30–400 kVA transformers: metering, feeders and reactive compensation with short-circuit, overload, over-voltage and residual-current protection — IP54, the grid-upgrade workhorse.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • GB/T 7251.2-2023 LV switchgear and controlgear assemblies — Part 2
  • GB/T 15576-2020 LV reactive-power compensation assemblies
  • Designation: integrated distribution box · transformer capacity · main-circuit scheme No.
At a glance

Built to perform, year after year

30 – 400 kVA
Transformer capacity
AC 400 V
Rated operating voltage
AC 220 / 380 V
Auxiliary-circuit voltage
50 Hz / ≤ 630 A
Rated frequency / current
A closer look

Engineered around safety, efficiency and uptime

Overview

The JP series outdoor integrated distribution box combines metering, outgoing feeders and reactive-power compensation in one unit, with built-in short-circuit, overload, over-voltage and residual-current protection. Compact, neat and economical, it mounts on the pole beside the distribution transformer — a new-generation product for urban and rural grid renovation.

Standards & designation

GB/T 7251.2-2023 LV switchgear and controlgear assemblies — Part 2
GB/T 15576-2020 LV reactive-power compensation assemblies
Designation: integrated distribution box · transformer capacity · main-circuit scheme No.

Internal configuration

Metering: energy meter, CTs, zero-sequence CT and terminal box
Protection & switching: isolator, residual-current breaker, miniature breakers, outlet AC contactor and air breaker
Compensation: capacitors with switching contactors
Hardware: incoming cable conduit, exposed/recessed door locks with rain-proof box

Service conditions

Ambient −25 °C … +40 °C; daily/monthly RH ≤ 90 %
Altitude ≤ 2000 m; site free of severe vibration, shock and corrosive gas

Technical specifications

Full specifications

Technical parameters
Transformer capacity
30 – 400 kVA
Rated operating voltage
AC 400 V
Auxiliary-circuit voltage
AC 220 / 380 V
Rated frequency / current
50 Hz / ≤ 630 A
Residual operating current
30–300 mA 可调
Protection grade
IP54
Horizontal cabinet sizes (L×W×H, mm)
30–100 kVA (schemes 01, 06)
800×450×700
30–250 kVA (schemes 02/04/07/09)
900×500×700

Specifications are representative and may vary by configuration and region. Final figures are confirmed on the project datasheet.

Ready to power your next project?

Tell us about your load profile and site conditions — our engineers will help you size the right HiStore configuration.