Load Switches

FLN36 SF6 Load Switch & Fuse Combination

Indoor SF6 load switch family (FLN36 / FLRN36, 12 & 24 kV) with Close-Open-Earth three-position interrupter, visible pressure gauge, safety diaphragm and optional touch-safe cable heads — to GB 3804 / GB 16926 / IEC 60265 / 60420.

Factory-direct supply Worldwide delivery & export documentation 12-month warranty · extended options
  • Switch and combination share the same epoxy-injected upper/lower housings forming the gas cavity; the common r
  • Front panel carries the SF6 gauge and a position indicator directly coupled to the contact shaft; a rear safet
  • Reliable mechanical interlocks: load switch ↔ earthing switch, earthing switch ↔ front door (for cabinet build
  • TII manual spring mechanism: upper hole earths, lower hole switches; closing charges the opening spring, relea
  • TII electric version adds motor charging and shunt-trip coil — manual and electric fully independent; AC220 /
At a glance

Built to perform, year after year

12(24) kV
Rated voltage
50Hz
Rated frequency
630 / 125A
Rated current (switch / fuse unit)
20 kA / 3 s
Load-switch short-time withstand
A closer look

Engineered around safety, efficiency and uptime

Overview

FLN36-12(24)D and FLRN36-12(24)D indoor AC HV SF6 load switches, switch-fuse combinations and cable-head-mountable variants were self-developed by absorbing advanced foreign technology against Chinese operating requirements, fully type-tested to GB 3804, GB 16926, IEC 60265 and IEC 60420. The three-position Close-Open-Earth interrupter offers reliable interlocking, high break insulation and large creepage; outlets carry voltage-equalising shields, and the cable-head variant fits touch-safe front connectors for cable distribution boxes. Special dynamic/static seals plus a visible SF6 pressure gauge keep operation safe — a new-generation switch for urban grids, serving 10/20 kV systems in industry, high-rises, residences and prefabricated substations.

Structure & mechanisms

Switch and combination share the same epoxy-injected upper/lower housings forming the gas cavity; the common rotating contact cycles Close-Open-Earth
Front panel carries the SF6 gauge and a position indicator directly coupled to the contact shaft; a rear safety diaphragm vents over-pressure to protect personnel
Reliable mechanical interlocks: load switch ↔ earthing switch, earthing switch ↔ front door (for cabinet builds)
TII manual spring mechanism: upper hole earths, lower hole switches; closing charges the opening spring, released only by button or fuse strike
TII electric version adds motor charging and shunt-trip coil — manual and electric fully independent; AC220 / DC220 / DC110 / DC48 V

Service conditions

Ambient −15 °C … +40 °C; altitude ≤ 1000 m (negotiate higher per GB/T 11022)
Daily RH ≤ 95 %, monthly ≤ 90 %; vapour pressure ≤ 2.2 / 1.8 kPa
Air free of dust, smoke, corrosive or flammable gas and salt mist; external vibration negligible; induced EMI in secondary ≤ 1.6 kV

Technical specifications

Full specifications

Main parameters (FLN36 / FLRN36)
Rated voltage
12(24) kV
Rated frequency
50 Hz
Rated current (switch / fuse unit)
630 / 125 A
Load-switch short-time withstand
20 kA / 3 s
Operating mechanism voltage
AC220 · DC220/110/48 V

Specifications are representative and may vary by configuration and region. Final figures are confirmed on the project datasheet.

Explore the range

See which model fits your project

Ready to power your next project?

Tell us about your load profile and site conditions — our engineers will help you size the right HiStore configuration.